top of page

EX PROOF LIGHTING EQUIPMENTS

APPLICATION


Series fluorescent lighting fitting are used in group II hazardous areas at indoor or outdoor services.

Series Lightıng Fixtures
ATEX 2014/34/EU

Execution: EX 3G nA IIC T4 Gc (-20 °C≤ Tamb ≤+55 °C)
                    EX tb IIIC T85 ºC Db
Installation: Zone 2 - Zone 22
Protection: Degree IP 66
Certificate Ref. TSE 16ATEX0030
Rules of compl. EN 60079-0:2012/A11:2013, EN 60079-15 : 2011, EN 60079-31:2014

ZONE 2 FLOURESCENTS

CLASSIFICATION: Group II - Category 3G/3D

                  Polycarbonate Body

APPLICATION


EVF.2 series fluorescent lighting fixtures are used in Group II hazardous areas at indoor or outdoor
services.

EVF.2 Series Lightıng Fixtures
ATEX 94/9/EC

Execution II 2 G Ex ed IIB Gb
II 2 D Ex IIIC IP 66 Db
Installation: Zone 1/2 - Zone 21/22
Protection Degree: IP 66
Certificate Ref. MP 11 ATEX 0084
Rules of compl. EN 60079-0:2012; EN 60079-7:2007; EN 60079-31:2009

EVF.2 FLOURESCENT

CLASSIFICATION Group II - Category 2G/2D

                         Two Fluorescent

APPLICATION

​

EVF.1X series fluorescent lighting fixtures are used in Group II hazardous areas at indoor or outdoor services

EVF Series Lightıng Fixtures

ATEX 94/9/EC

Execution:II 2 G Ex ed IIB Gb

II 2 D Ex IIIC IP 66 Db

Installation:ı Zone 1/2 - Zone 21/22

Protection Degree: IP 66

Certificate Ref. MP 11 ATEX 0084

Rules of compl. EN 60079-0:2012; EN 60079-7:2007; EN 60079-31:2009

EVF.1 FLOURESCENT

CLASSIFICATION Group II - Category 2G/2D

                               Single Fluorescent

APPLICATION


EVF.EM series fluorescent lighting fixtures are used in Group II hazardous areas with one or three hours
Emergency Kit at indoor or outdoor services.

EVF Series Lightıng Fixtures
ATEX 94/9/EC

Execution: II 2 G Ex ed IIB Gb
II 2 D Ex IIIC IP 66 Db
Installation: Zone 1/2 - Zone 21/22
Protection Degree: IP 66
Certificate Ref. MP 11 ATEX 0084
Rules of compl. EN 60079-0:2012; EN 60079-7:2007; EN 60079-31:

EVF.EM FLOURESCENT

CLASSIFICATION Group II - Category 2G/2D

                          With Emergency Kit

APPLICATION


EVF.CX  series  fluorescent  lighting  fixtures  are  used in  Group  II  hazardous  areas  at  indoor  or  outdoor services

EVF Series Lightıng Fixtures
ATEX 94/9/EC

Execution: II 2 G Ex ed IIB Gb
II 2 D Ex IIIC IP 66 Db
Installation: Zone 1/2 - Zone 21/22
Protection Degree: IP 66
Certificate Ref. MP 11 ATEX 0084
Rules of compl. EN 60079-0:2012; EN 60079-7:2007; EN 60079-31:2009

EVF.CX FLOURESCENT

CLASSIFICATION Group II - Category 2G/2D

                       Compact Fluorescent

APPLICATION


EVF.LX series fluorescent lighting fixtures are used in Group II hazardous areas at indoor or outdoor
services.

EVF Series Lightıng Fixtures
ATEX 94/9/EC

Execution: II 2 G Ex ed IIB Gb
II 2 D Ex IIIC IP 66 Db
Installation:Zone 1/2 - Zone 21/22
Protection Degree: IP 66
Certificate Ref.:MP 11 ATEX 0084
Rules of compl.:EN 60079-0:2012; EN 60079-7:2007; EN 60079-31:2009

EVF.LX FLOURESCENT

CLASSIFICATION Group II - Category 2G/2D

                       Ceiling Mounted

APPLICATION


EV.W series incandescent or compact fluorescent lighting fixtures are used in Group II hazardous areas at indoor or outdoor services.

EV Series Lightıng Fixtures
ATEX 94/9/EC

Execution: II 2 G Ex d IIB Gb
II 2 D Ex t IIIC IP 67 Db
Installation: Zone 1/2 - Zone 21/22
Protection Degree: IP 67
Certificate Ref.: MP 11 ATEX 0077.X
Rules of compl.: EN 60079-0:2012; EN 60079-1:2007; EN 60079-31:2009

WALL MOUNTED FIXTURE

CLASSIFICATION Group II - Category 2G/2D

                  Wall Mounted 45° - 90°

APPLICATION

​

EV.BA series incandescent or compact fluorescent lighting fixtures are used in Group II hazardous areas at indoor or outdoor services.

EV Series Lightıng Fixtures
ATEX 94/9/EC

Execution: II 2 G Ex d IIB Gb
II 2 D Ex t IIIC IP 67 Db
Installation: Zone 1/2 - Zone 21/22
Protection Degree: IP 67
Certificate Ref.: MP 11 ATEX 0077.X
Rules of compl.: EN 60079-0:2012; EN 60079-1:2007; EN 60079-31:2009

ANGLED CONDUIT MOUNTED FIXTURE 

CLASSIFICATION Group II - Category 2G/2D

                   Conduit Mounted 60°

APPLICATION


EV.C series incandescent or compact fluorescent lighting fixtures are used in Group II hazardous areas at indoor or outdoor services.

EV Series Lightıng Fixtures
ATEX 94/9/EC

Execution:
Installatioz: Zone 1/2 - Zone 21/22
Protection Degree: IP 67
Certificate Ref. MP 11 ATEX 0077.X
Rules of compl. EN 60079-0:2012; EN 60079-1:2007; EN 60079-31:2009

CEILING MOUNTED FIXTURES

CLASSIFICATION Group II - Category 2G/2D

                       Ceiling Mounted

APPLICATION


EV.B series incandescent or compact fluorescent lighting fixtures are used in Group II hazardous areas at indoor or outdoor services.

EV Series Lightıng Fixtures
ATEX 94/9/EC

Execution:
Installation: Zone 1/2 - Zone 21/22
Protection Degree: Sınıfı IP 67
Certificate Ref. MP 11 ATEX 0077.X
Rules of compl. EN 60079-0:2012; EN 60079-1:2007; EN 60079-31:2009

CONDUIT MOUNTED FIXTURES

CLASSIFICATION Group II - Category 2G/2D

                      Conduit Mounted

PORTABLE/HANDLE FIXTURE

CLASSIFICATION Group II - Category 2G/2D

                                 Portable

APPLICATION


EV.P series incandescent or compact fluorescent lighting fixtures are used in Group II hazardous areas at indoor or outdoor services.

EV Series Lightıng Fixtures
ATEX 94/9/EC

Execution:
Installation: Zone 1/2 - Zone 21/22
Protection Degree: IP 67
Certificate Ref. MP 11 ATEX 0077.X
Rules of compl. EN 60079-0:2012; EN 60079-1:2007; EN 60079-31:2009

APPLICATION


EV.BW series sodium, metal halide or mercury vapor lighting fixtures are used in Group II hazardous areas at indoor or outdoor services.

EV.BW series lighting fittings are use with ballast in separate enclosures.

EV Series Lightıng Fixtures
ATEX 94/9/EC

Execution: II 2 G Ex d IIB Gb
II 2 D Ex t IIIC IP 67 Db
Installation: Zone 1/2 - Zone 21/22
Protection Degree: IP 67
Certificate Ref.: MP 11 ATEX 0077.X
Rules of compl.:EN 60079-0:2012; EN 60079-1:2007; EN 60079-31:2009

GLOBE WITH BALLAST

CLASSIFICATION Group II - Category 2G/2D

           Wall Mounted With Ballast

APPLICATION


EV.BC series sodium, metal halide or mercury vapor lighting fixtures are used in Group II hazardous areas at indoor or outdoor services.

EV.BC series lighting fittings are use with ballast in separate enclosures.

EV Series Lightıng Fixtures
ATEX 94/9/EC

Execution:
II 2 G Ex d IIB Gb
II 2 D Ex t IIIC IP 67 Db
Installation: Zone 1/2 - Zone 21/22
Protection Degree: IP 67
Certificate Ref.: MP 11 ATEX 0077.X
Rules of compl.: EN 60079-0:2012; EN 60079-1:2007; EN 60079-31:2009

GLOBE WITH BALLAST

CLASSIFICATION Group II - Category 2G/2D

                Ceiling mounted With Ballast

APPLICATION


EPFP.X series lighting fixtures are used in Group II hazardous areas at indoor or outdoor services.
EV Series Lightıng Fixtures
ATEX 94/9/EC
Execution: II 2 G Ex d IIB Gb
II 2 D Ex t IIIB IP 54 Db
Installation: Zone 1/2 - Zone 21/22
Protection Degree: IP 54
Certificate Ref.: MP 11 ATEX 0087.X
Rules of compl.: EN 60079-0:2012; EN 60079-1:2007; EN 60079-31:2009

EPFP.X PROJECTOR

CLASSIFICATION: Group II - Category 2G/2D

                           PROJECTOR

bottom of page